Checkpoint Buttons and Guard Keys: Mounting, Placement and How Many You Need
A practical guide to the two tags that make a guard tour record: how to mount WM-90A iButton and WM-30A RFID checkpoints, where to place them, how many a route needs, and how guard keys put a name on every scan.
A checkpoint button is the small fixed tag a guard has to touch or scan to prove he reached a place. It is the cheapest part of a guard tour system and the one that decides whether the records are worth anything: a reader that works perfectly still proves nothing if the tags sit in the wrong places, at the wrong height, or keep falling off the wall. This guide covers the two tags that make a record, the checkpoint button (where) and the guard key (who), and how to mount, place and count them.
Two tags, two different jobs
Every scan writes one line: a place, a person and a time. The checkpoint button supplies the place, the guard key supplies the person. Both are passive read-only tags with no battery and no wiring, and both are read by the same reader, so a route costs only the tags and the screws.
| WM-90A contact checkpoint | WM-30A RFID checkpoint | |
|---|---|---|
| Tag | iButton DS1990A-F5 chip | Passive 125 kHz RFID disc |
| How it is read | The reader tip touches the chip | The reader is held a few centimetres away |
| Size | 47 × 32 mm plate, 16 mm chip | 30 mm disc, 4 mm thick, 5 mm centre hole |
| Fixing | 2 screws in 6 mm holes | 1 screw in a 4 mm hole, or adhesive |
| Radio energy | None | 125 kHz field |
| Weight | 1.6 g | 2.8 g |
| Best for | Fuel, chemical and explosive zones | General buildings, warehouses, yards |
Mounting a contact checkpoint (WM-90A)
The WM-90A is a stainless iButton chip set into a plastic wall plate. Because the reader has to touch the chip, the plate must sit exactly where the guard will stop, not above his head and not down at skirting level.
- Choose the spot at chest height, about 1.2 m from the floor, on the wall beside the door, valve or cabinet the round is meant to check.
- Hold the plate against the wall, mark the two holes with a pencil and drill them at 6 mm.
- Push in the wall plugs and screw the plate down. Two screws matter: a screwed plate cannot be peeled off or quietly moved to another door.
- Touch the reader tip to the chip and confirm the record appears under the right checkpoint name before moving on.

Mounting an RFID checkpoint (WM-30A)
The WM-30A is a passive 125 kHz disc with a single centre hole. It needs no contact, so it can be fixed to awkward surfaces: a post, a pipe guard, the inside of a riser cupboard.
- Drive one screw through the 5 mm centre hole, or stick the disc down with the adhesive pad where drilling is not allowed.
- Mount it about 1.2 m above the floor, within arm reach, on a surface the guard passes on every round.
- Keep it off bare steel. A steel plate detunes the antenna and shortens the read range, so use the anti-metal version on racking, doors and machine frames.
- Add the night-glow ring on unlit routes so the point can still be found with the torch off.

Where a checkpoint should go
Placement decides whether the tag is actually touched. Four rules cover most sites:
- Put the tag at the thing you want proof of: the fire exit door, the valve, the extinguisher, the roof hatch. Not in the middle of a corridor.
- Put it where the guard already stops. If he has to hunt for it, it will be skipped and the report will show a missed point.
- Keep it dry: out of standing water, away from hose spray, and under a shelter if it is outdoors.
- Make it findable. A night-glow ring or a small numbered label matters more than it sounds on a 3 a.m. round.
How many checkpoints does a route need?
Count places, not metres. A route needs one checkpoint for every place where a person must physically stand: each entrance, each plant room, each floor landing, each high-value store, each outdoor gate. A five-floor office with one entrance, one plant room per floor and a roof hatch comes to about eight checkpoints, not fifty.
Both extremes fail. Too few tags and a single point at the end of a 200 m corridor proves almost nothing. Too many and the guard spends the shift walking between tags instead of looking at anything. A practical test: walk the route as the guard would, and stop wherever you would want a photograph. Those stops are the checkpoints.
Guard keys: one tag per person
The guard key is the same idea in a keyring fob, one per guard, read by the same reader. With a key in the record, a scan says who walked the route, not just that somebody did. The WM-90S uses the iButton chip and is read by contact readers; the WM-226 uses a 125 kHz RFID tag and is read by the RFID range.
| WM-90S iButton guard key | WM-226 RFID guard key | |
|---|---|---|
| Tag | DS1990A-F5 iButton chip | Passive 125 kHz RFID tag |
| Size | 21 × 55 mm | 36 × 28 × 6 mm |
| Housing | Black keyring fob | Yellow keyring fob |
| Weight | 4.4 g | 3.8 g |
| ID | Factory-fixed serial, not rewritable | Factory-fixed serial, not rewritable |

Binding, lending and lost keys
Each key is bound to one name in the guard tour management system. That binding is the whole point: a colleague cannot borrow a key and have the round recorded as his own, because the serial is fixed inside the chip. When a key is lost, issue a new one and bind it to the same guard. The checkpoints stay where they are and the history stays intact. Keep one spare key on site.
When a checkpoint will not read
| Symptom | Likely cause | What to do |
|---|---|---|
| Contact reader gives no confirmation | Dirty chip, or the tip is not square on the chip | Wipe the chip with a dry cloth, press the tip flat and hold for a moment |
| Reads sometimes, misses others | Plate loose or chip pushed back into the wall | Tighten the two screws and reseat the plate |
| RFID tag reads only at touching distance | Tag on steel, or weak reader battery | Fit the anti-metal version, replace the reader batteries |
| Record shows the wrong checkpoint | Two tags swapped during installation | Re-label the tags and correct the mapping in the software |
| Nothing reads in winter | Ice film over the chip or disc | Clear the ice and shelter the plate from drip |
Buying checklist
- Count checkpoints per route, then add about 10 percent as spares for damaged or new points.
- Choose contact tags for fuel, chemical and explosive zones. They emit no radio energy.
- Match the fixing to the wall: two screws for masonry, adhesive pad for glass and panels, anti-metal for steel.
- Order night-glow rings for unlit outdoor routes.
- Order one guard key per person plus one spare, and label each key with the guard name.
- Ask for a printed checkpoint list so the installer and the software use the same names.
Frequently asked questions
Do checkpoint buttons need power or batteries? No. Both the iButton chip and the RFID disc are passive: the reader supplies the small amount of energy needed to read the serial, so a tag mounted today can stay on the wall for twenty years without service.
Can a guard copy a checkpoint button? The serial is written at the factory and cannot be edited, and a copied chip carries a different serial, so a fake tag produces a record that does not match the route. Screwing the plate down also removes the easier trick of moving the tag to another door.
Can checkpoints be moved later? Yes, but re-map them. The serial belongs to the tag, not to the wall, so a moved tag still reports its old name until you update the checkpoint list in the software.
iButton or RFID in a warehouse with steel racking? RFID needs the anti-metal version or a spacer on steel, while the contact iButton is unaffected by metal. If the warehouse also handles solvents or gas, contact is the safer choice anyway.